- Overview
- Product Description
- Related Products
- About Us
Basic Info.
Model NO.
AC-868
Reading Distance
3-5cm
Application
Parking, Hospital, Library, Company, Bank, Store
Working Power
DC 9-20V 0.3A@12V
Operating Temperature
-10ºC-+65ºC
Degree of Protection
IP65
Number of Cards Saved
16000
Display Method
DOT Matrix LCD Screen with Backlight
Language Type
Traditional Chinese/English
Number of Keys
16 Keys(10 Numeric Keys, *#, 4 Function Keys)
RS485 Interface
1, Available for Device Updates
Ethernet Interface
Reserved(Optional)
Wiegand in Put Interface
1
Alarm Output Interface
1, No/Nc Optional
Non-Isolated Input Interface
4
Oc Output Interface
6
Size
128X87X46mm
Door Open Outpu
1, Including COM/No/Nc
Transport Package
Cartons
Specification
11.35*4.68*4.77cm
Trademark
JUTAI
Origin
China
HS Code
9031809090
Production Capacity
500000/Year
Packaging & Delivery
Package Size
14.00cm * 11.00cm * 6.00cm
Package Gross Weight
0.500kg
Product Description
1. Product Introduction
AC-868 standalone reader, which can be used independently. It has a built-in LCD screen, which can display the card number, and can be customized by the enterprise LOGO, integrated password keyboard, support card swiping and key password to open the door , can encrypt 13. 56MHz, support EM card and MIFARE card, easy to use, reliable data storage, integrated with management and automatic control, widely used in offices, supermarkets, shopping malls,scenic spots, automatic doors and other fields.2.Packing List
Name | Specification | Quantity |
AC-868 | 1 | |
Manual | 1 | |
Wall plug | 4 | |
Screw | Ф 3mmX25mm | 4 |
Waterproof silicone strip | Ф 2mm | 1 |
3.Features
Features | Description |
Large capacity | Can support 16000 card number storage |
LCD liquid crystal display | Can easily display the card number, and corporate LOGO |
Support serial number storage card | Improve the efficiency of card number entry |
Various ways to open the door | Flexible door opening methods, support card swiping, password or card+password |
Easy to use | Adding and deleting cards can be easily realized without a computer |
Wide range of applications | Door entry control, gate access, barrier gate control, access management applications |
Card reading type | EM card/Mifare card(can be setting) |
Encryption frequency | 13.56MHz |
4.Size
5. Card Operation
Note: The initial password is: *123456#, in the settings, * is the return key, # is the confirmation key
1. Enter Card
ID code entry | Pass * Password # 1 1 User address # Enter the first 5 digits of the ID code #Enter the last 5 digits of the ID code # |
Card induction entry (continuous card number) | Pass * Password # 1 2 Input start addr # Set the number of sheets# 1 #Credit card # |
Card induction entry (discontinuous card number) | Pass * Password # 1 2 Input start addr # Set the number of sheets #0 #Credit card Credit card.... # |
2. Pause Card
Address range pause | Pass* Password # 1 3 Input start addr # Input end addr # |
ID code suspension | Pass * Password # 14 # Enter the first 5 digits of the ID code #Enter the last 5 digits of the ID code # |
3. Remove Card
Address range removal | Pass * Password # 1 5 Input start addr I # Input end addr # |
ID code removal | Pass * Password # 1 6 Enter the first 5 digits of the ID code # Enter the last 5 digits of the ID code # |
4. Recovery Card
Address range restoration | Pass * Password # 17 Input start addr # Input end addr # |
ID code recovery | Pass * Password # 1 8 Enter the first 5 digits of the ID code # Enter the last 5 digits of the ID code # |
5. One-ln-One-Out Control
Enable control | Pass * Password # 1 9 Input start addr # Input endaddr # 1 # |
Disable control | Pass a Password # 1 9 Input start addr # Input end addr#0 # |
6. User information
Password | Pass * Password # 2 1 User address # Input password # | |
Set card opening method | Invalid | Pass * Password # 2 2 Input start addr # Input end addr # 0 # |
Card | Pass * Password # 2 2 Input start addr # Input end addr # 1 # | |
Card or PIN | Pass * Password # 2 2 Input start addr # Input end addr # 2 # | |
Card & PIN | Pass * Password # 2 2 Input start addr # Input end addr # 3 # | |
Extend options | Disable one-in-one-out control | Pass * Password # 2 3 Input start addr # 0 # |
Enable one-in-one-out control | Pass * Password # 2 3 Input start addr# 1 # | |
Note: Patrol card is an item that can be set but has no function |
7. Card Machine Parameters(1)
Onoff openzone | Disable timed door opening | Pass * Password # 3 2 0 # 0 # 0 # 0 # |
Enable timed door opening | Pass * Password # 3 2 1 # 1 # 1 # 1 # | |
Door lock action time setting | Pass * Password # 3 3 Enter the action time of the main controller # Enter WG action time # | |
Door opening waiting time setting | Pass * Password # 3 4 Enter the number of seconds the host controller waits #Enter the number of seconds to wait for WG # | |
Alarm output action time setting | Pass * Password # 3 5 Input alarm output action seconds # | |
Alarm output delay time setting | Pass * Password # 3 6 Enter the number of seconds to delay the alarm output # | |
Alarm start delay time setting | Pass * Password # 3 7 Enter the number of seconds to delay the start of the guard # Input warning output interval time # | |
Alert password setting | Pass * Password # 3 8 Enter alert password | |
User password length setting | Pass * Password # 3 9 Enter user password length # Enter the card number byte length # Enter card number display format (0: NO , 1:WG , 2: ABA , 3: HEX ,4: WG26 , 5: ABA8) # |
8. Card Machine Parameters(2)
Automatic door lock setting | Disable auto-lock | Pass * Password # 4 1 0 # 0 # |
Enable auto-lock | Pass * Password # 4 1 1 # 1 # | |
Door open button enable setting | Disable door open button | Pass * Password # 4 2 0 # 0 # |
Enable door open button | Pass * Password # 4 2 1 # 1 # | |
Miscellaneous settings | Prohibit any card reading card | Pass * Password # 4 3 0 # 0 # Enter whether the Wiegand and the main controller share the door (0: NO,1: YES) # Enter the interval time between repeated reading of the same card # Enter the maximum number of continuous input errors within 30 seconds # |
Enable any card reader row | Pass * Password # 4 3 1 # 1 # Enter whether the Wiegand and the main controller share the door (0: NO, 1:YES) # Enter the interval time between repeated reading of the same card # Enter the maximum number of continuous input errors within 30 seconds # | |
Note: Time attendance, verify password, button to open the door, all can be st but has no function | ||
Forced door opening alarm setting | Deactivate forced open door to generate alarm | Pass * Password # 4 4 0 # 0 # |
Enable forced door opening to generate alarm | Pass * Password # 4 4 1 # 1 # | |
Close the door to cancel the alarm setting | Deactivate close the door to disarm the alarm | Pass * Password # 4 5 0 # 0 # |
Enable door close to dismiss alarm | Pass * Password # 4 5 1 # 1 # | |
one in one out control | Disable one-in-one-out control | Pass * Password # 4 6 0 # Enter the control direction of the main controller (0: exit, 1 entry) # 0 # Enter the WG system direction (0: exit, 1: entry) # |
Enable one-in-one-out control | Pass * Password # 4 6 1 # Enter the control direction of the main controller (0: exit, 1 entry) # 1 # Enter the WG system direction (0: exit, 1: entry) # | |
restore factory default | Pass * Password # 49 Enter the item to factory reset (0: system parameters, 1: user settings, 2: system & user) |
9. Toolbox
language settings | Chinese | Pass * Password # 5 1 0 # |
English | Pass * Password # 5 1 1 # | |
Administrator password setting | Pass * Password # 5 2 Enter password # | |
Administrator scope settings | Pass * Password # 5 3 Enter starting address # Enter end address # | |
Opening hours setting | Pass * Password # 5 6 Input group # Enter the time (within 24 hours), whether the input host is valid (0: invalid, 1: valid) # Enter the cycle in sequence (0: invalid, 1: valid) # | |
View system information | Pass * Password # 5 7 | |
Clock setting | Pass * Password # 5 8 Follow the date(year-month-day), and then enter the time(hour,minute,second)in turn # Enter date display mode (0:day/month, 1:month/day) # | |
Back to main page | Pass * Password # 6 | |
Set alert | Pass * Password # 7 |
10. Products Parameters
Working power | DC 9-20V (with reverse polarity protection) 0.3A@12V |
Operating temperature | -10"C~+65'C |
Degree of protection | IP65 |
Number of cards saved | 16000 |
Display method | Dot matrix LCD screen with backlight |
Language type | Traditional chinese/english |
Number of keys | 16 keys (10 numeric keys, *#, 4 function keys) |
RS485 interface | 1, available for device updates |
Ethernet interface | Reserved (optional) |
Wiegand input interface | 1 |
Door open output interface | 1, including COM/NO/NC |
Alarm output interface | 1, NO/NC optional |
Non-isolated input interface | 4 |
OC output interface | 6 |
LED status indication | Power indicator, alarm indicator, error indicator, warning indicator, cardreading indicator, programming mode indicator |
Size | 128X87X46mm |
11. Definition Of Wiring
12. Product Application Scenarios
1. Access Control Application (Anode Lock)
2. Access Control Application (Cathode Lock)
3. Access Control Application (Magnetic Lock)
4. Application Of Connecting Gate (JUTAI BR-110)
5. Wiring Diagram Of the Whole Set Of Access Control Application System
Certificate
Thank you for considering JUTAI as a potential partner. We look forward to the opportunity of working together and contributing to your continued success.
More and More Details Info Please Scan JUTAI Offical QR Code: