Basic Info.
Model NO.
Energy Storage
Rechargeable
Chargeable
Cooling Method
Air Cooling
Power
33.12kwh
Voltage
DC Bus Side 42vd-58VDC
Atmospheric Pressure
61kp-113kpa
Protection Level
IP21
Relative Humidity
<95%
Mtbf
>100000 Hours
Efficiency
>95%
Overcurrent Protection
Max:150A
Installation Environment
Indoor
Lightning Protection
Yd5098-2005
Transport Package
Wooding
Specification
680mm*489.5mm*1528mm
Trademark
SINEE
Origin
China
Production Capacity
100000pieces/Year
Product Description
Innovative Power Solutions for Network Distribution Points
provide one-stop system solutions
Independent Control:Each group of batteries is independently controlled, without risk of circulation
Perfectly Compatible:Compatible with mainstream batteries on the market, allowing batteries of different types, capacities and batches to be used in parallel
Safe and Stable:Thermal runaway warning/DC circuit breaker/explosion-proof structure triple protection design
Minimalist Deployment:Modular design enables quick disassembly and assembly, and it only takes 15 minutes to complete the installation of a base station
Frontal Maintenance:No need to reserve maintenance channels, supports full frontal maintenance, and frees up base station space.
Intelligent Operation:Thousands of stations are interconnected to accurately calculate energy storage revenue, remotely monitor equipment status, and achieve efficient operation and maintenance.
The one-stop energy storage system for communication base stations is specially designed for base station energy storage. Users can use the energy storage system to discharge during load peak periods and charge from the grid during low load periods, reducing peak load demand and saving electricity costs, thus achieving the purpose of improving load characteristics and participating in system peak regulation, while saving electricity costs and maximizing arbitrage.
System Integration:Integrate EMS / BMS / PCS / power distribution / battery / operation platform toprovide one-stop system solutions
Independent Control:Each group of batteries is independently controlled, without risk of circulation
Perfectly Compatible:Compatible with mainstream batteries on the market, allowing batteries of different types, capacities and batches to be used in parallel
Safe and Stable:Thermal runaway warning/DC circuit breaker/explosion-proof structure triple protection design
Minimalist Deployment:Modular design enables quick disassembly and assembly, and it only takes 15 minutes to complete the installation of a base station
Frontal Maintenance:No need to reserve maintenance channels, supports full frontal maintenance, and frees up base station space.
Intelligent Operation:Thousands of stations are interconnected to accurately calculate energy storage revenue, remotely monitor equipment status, and achieve efficient operation and maintenance.
Lead Carbon System | Lithium Battery System | ||
Mechanical Properties | Specification | Rack mount | Rack mount |
Weight | 860kg (2V500Ah 22 pieces/group system) Modular capacity can be increased according to needs | 370kg (3.2V230Ah 15 pieces/group system, 3 groups) can be modularly expanded according to needs | |
Size(L*W*H) | 1040mm*540mm*1485mm | 680mm*489.5mm*1528mm | |
Cooling Method | Air Cooling | Air Cooling | |
Electrical characteristics | Power | 22kWh | 33.12KWh |
Voltage | DC bus side: 42VDC~58VDC | DC bus side: 42VDC~58VDC | |
Energy storage battery pack: 38.5VDC~53.9VDC | Energy storage battery pack: 38.5VDC~53.9VDC | ||
Current | Charging: 1A~109A, discharging: 0A~95A | Charging: 1A~109A, discharging: 0A~95A | |
Voltage stabilization accuracy | ≤1% | ≤1% | |
Overcurrent protection | Max:150A | Max:150A | |
Power | 6kW, 12kW, 18kW, 24kW, optional configurations | 6kW, 12kW, 18kW, 24kW, optional configurations | |
Efficiency | ≥95% | ≥95% | |
Output ripple peak to peak | Ripple peak-to-peak value ≤200mV (YD/T 731) | Ripple peak-to-peak value ≤200mV (YD/T 731) | |
MTBF | >100000 Hours (25ºC) | >100000 Hours (25ºC) | |
Northbound communication external interface | Communication method: Isolated RS485*1 | Communication method: Isolated RS485*1 | |
Support protocol content: support modbus protocol format | Support protocol content: support modbus protocol format | ||
Southbound communication external interface | Communication method: Isolated RS485*1 | Communication method: Isolated RS485*1 | |
Usage Environment | Ambient Temperature | -20-50ºC (working around 25ºC) | -20-50ºC (working around 25ºC) |
Relative humidity | ≤95% | ≤95% | |
Atmospheric Pressure | 61kPa~113kPa | 61kPa~113kPa | |
Installation Environment | Indoor | Indoor | |
Protection Level | IP21 | IP21 | |
EMC | Electrostatic discharge immunity type | GB/T 17626.2-2018 Level 4 requirements | GB/T 17626.2-2018 Level 4 requirements |
Conducted disturbance limits | GB 9254-2008 CLASS A | GB 9254-2008 CLASS A | |
Radiation disturbance limits | GB 9254-2008 CLASS B | GB 9254-2008 CLASS B | |
Surge (impact) anti-interference | GB/T 17626.5-2019 | GB/T 17626.5-2019 | |
Lightning protection | YD5098-2005 | YD5098-2005 |