Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H

Customization: Available
Certification: ISO9001, CE
Salt Rejection Rate: 99.5%

Products Details

Basic Info.

Model NO.
WTRO-5T
Function
Remove Impurities,Desalting,Deionizing
Principle
Reverse Osmosis,EDI,Ion Exchange
Force
Pressure Difference,Potential Difference
Recovery Rate
(Permeate Flow / Feed Flow) X 100%
Material
UPVC+Stainless Steel/FRP
Warranty
One Year
Service
Lifetime Technology Support
Transport Package
Wooden Case
Specification
RO+RO+EDI (0.5-10t/h)
Trademark
Wentong
Origin
Wenzhou, China
HS Code
8421219990
Production Capacity
800sets/Year

Product Description

 RO and EDI Ultrapure Water System

Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H
The central pure water equipment of the hospital ultrapure water equipment is a multifunctional automatic device composed of a pretreatment system, a reverse osmosis pure water system, an EDI deep desalination system, a post-treatment system, and a circulating water supply system. It is safe, convenient to use, low-cost operation, and fully automatic equipment with stable production water quality.
The system adopts full automatic control (manual control can also be used), and automatic backwashing and regeneration procedures can be set when the system is running; the first-stage reverse osmosis and the second-stage reverse osmosis are equipped with return pipes, and the reverse osmosis equipment is equipped with chemical cleaning devices and The reverse osmosis membrane of the disinfection device adopts the reverse osmosis membrane imported from the United States to ensure the long-term stable operation of the reverse osmosis equipment; the reverse osmosis pipeline uses high-quality materials such as stainless steel and UPVC; it is installed in both the first-stage reverse osmosis equipment and the second-stage reverse osmosis equipment
There is an online conductivity detector; the reverse osmosis system is equipped with low-pressure protection and high-pressure protection switches; the reverse osmosis water recovery rate is adjustable, the primary reverse osmosis recovery rate is 60-70%, and the secondary reverse osmosis recovery rate is 70-80%; The pipeline is equipped with an ultraviolet sterilizer and a microporous filter to ensure that pure water meets sanitary requirements.

 
Product name Ultrapure Water Treatment Equipment
Size According to requirements
Configuration raw water tank,water pump,multi media filter,activated carbon filter,softener,cartridge filter,high pressure pump,UF unit,RO unit, EDI unit,polishing mixed bed,dosing system,washing pump and tank,pure water tank,UV sterilizer,Ozone sterilizer, instruments and other accessories.
Material UPVC + Stainless steel,FRP

Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H

Technical Parameter
Model Flow rate (L/h) Power(KW) Water use efficiency RO membrane Dimension 
L X W X H(mm)
RO-500L 500 1.5 ≥ 50% 4040 1650X630X1800
RO-750L 750 2.5 ≥ 50% 4040 1870X630X1850
RO-1000L 1000 2.5 ≥ 50% 4040 1870X650X1850
RO-2000L 2000 3.5 ≥ 50% 4040 2440X650X1750
RO-3000L 3000 4 ≥ 50% 4040 2440X620X1850
RO-5000L 5000 7.5 ≥ 50% 8040 2000X900X1800
RO-6000L 6000 9.5 ≥ 60% 8040 3000X900X1800
RO-8000L 8000 13.5 ≥ 60% 8040 3000×900×1800
RO-9000L 9000 14 ≥ 60% 8040 4000X900X1800
RO-10T 10T/H 19 ≥ 60% 8040 3000X900X1800
RO-12T 12T/H 19.5 ≥ 60% 8040 4000X900X1800
RO-15T 15T/H 23 ≥ 60% 8040 4000X900X1950
RO-20T 20T/H 28 ≥ 60% 8040 5000X900X1950
RO-30T 30T/H 55 ≥ 60% 8040 7000X900X1950

System process flow
1.Pretreatment→UV sterilization device→first-level RO device→second-level RO device→intermediate water tank→EDI device→deoxygenation device→nitrogen-sealed pure water tank→TOC UV removal device→polishing mixed bed→ultrafiltration device→water point
2. Pretreatment → reverse osmosis → intermediate water tank → water pump → EDI device → purified water tank → pure water pump → ultraviolet sterilizer → polishing mixed bed → 0.2 or 0.5μm precision filter → water object (≥18MΩ.CM)
3. Pretreatment → first-level reverse osmosis → dosing machine (PH adjustment) → intermediate water tank → second-level reverse osmosis (positive charge reverse osmosis membrane) → pure water tank → pure water pump → EDI device → ultraviolet sterilizer → 0.2 or 0.5μm precision filter → water object (≥17MΩ.CM)
4. Pretreatment → reverse osmosis → intermediate water tank → water pump → EDI device → pure water tank → pure water pump → ultraviolet sterilizer → 0.2 or 0.5 μm precision filter → water object (≥15MΩ.CM)
 
Water treatment equipment show
Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/HHospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/HHospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H




Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/HHospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H


Hospital RO and EDI Ultrapure Water Treatment System 500L/H-10000L/H

FAQ
1. Q: What products you provide? 
    A: We are specialized in RO system, EDI system, UF system, Sewage water treatment equipment, etc.
2. Q: What's the information you need before order? 
    A1: what's your raw water ? 
    A2: what's the capacity per hour of the equipment ? 
    A3: What's the application of purifier water ?
3. Q: How long is your delivery time?
    A: Generally it is 30 days, Depends on your project.


For more information
Wenzhou HengTong Water Treatment CO.,LTD.
ADD:No.922,Jinhai 2nd Avenue,Airport New District,Wenzhou, Zhejiang  
 
 
 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours