Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Customization: Available
Task: Program
Signal: Continuous

Products Details

Basic Info.

Model NO.
HiaGuard SIL3 SIS
Degraded Mode
3-2-0
Power Supply
1+1 Redundant Power Supply
System Availability
99.999%
Modular Design
Triple-Modular
Transport Package
Transported in Standard Packaging
Trademark
HollySys
Origin
China
HS Code
8537101101
Production Capacity
8, 000 Sets/Year

Product Description

HiaGuard system is a safety instrumented system developed by HollySys Group for the field of industrial automation safety, the first safety instrumented system with all intellectual property rights in China, and was certifi ed by TÜV (Rheinland Industrie Service GmbH) in 2012. HiaGuard is a programmable electronic system (PES) as defi ned by IEC 61508, which meet the SC3 (system capability level) and SIL3 (hardware safety integrity level) as defined by IEC 61508, and is applicable to safety-related applications in low operating modes up to SIL3 as defi ned by IEC 61508.

Features
High Safety
·  2 out of 3 with diagnostics(2oo3D), which ensures system safety
·  Data stream multi-voting
·  Triple-modular design, which ensures relative independence physically to avoid common causes
·  High diagnostic coverage
·  Built-in fi rewall in communication module

High Availability
·  Degraded operation is allowed, with a degraded mode of 3-2-0
·  Independent power is supplied at system side and fi eld side
·  1+1 redundant power supply
·  Communication module and I/O module support redundant confi guration and undisturbed switching
·  System availability is up to 99.999%

Powerful SOE Function
·  DI module has hard SOE function
·  DI module can cache 1000 SOE records
·  Control station can store 10,000 SOE records
·  SOE accuracy is up to 1 ms

High Diagnostic Coverage
·  Fault diagnosis can be located at the channel level
·  AI channel supports over-limit, break and short diagnosis
·  DI channel supports external cable grounding, disconnection and short diagnosis
·  DO channel supports on-site no-load, overload and short diagnosis
·  PI channel supports disconnection diagnosis and over-lower limit diagnosis

Optimal System Integration
·  Integration with the HOLLiAS-MACS system
·  Support integration with third-party DCS through Modbus interface

Extendable System Scale
·  A single station supports a maximum of 1 Main rack + 6 extension racks, with up to 1856 I/O points
·  A single domain supports up to 64 stations and 15 domains

Technical Specifications
System Hardware
Product Model Description
Power module QS10 System power module, 24V DC/240W
QS20 Field power module, 24V DC/480W
PRO MAX 240W 24V 10A System power module, 24V DC/240W
PRO MAX 480W 24V 20A Field power module, 24V DC/480W
Rack SGM101 Main rack
SGM110 Extension rack
Controller SGM201 Controller
Communication module SGM210 System communication module
SGM220 Remote I/O communication module (multimode optical fiber)
SGM221 Remote I/O communication module (triple-port mono-mode optical fiber)
SGM222 Remote I/O communication module (mono -port mono-mode optical fiber)
SGM230 Modbus communication module
SGM240 IO communication trunk module
I/O module SGM410 16-channel analog input module
SGM410H 16-channel analog input module with HART function
SGM412H 32-channel analog input module with HART function
SGM520 8-channel analog output module
SGM520H 8-channel analog output module with HART function
SGM610 32-channel DI module
SGM710 32-channel DO module
SGM633 Pulse input and overspeed protection module
I/O terminal board SGM3410 16-channel analog input terminal module
SGM3410H 16-channel analog input terminal module with HART function
SGM3412H 32-channel analog input terminal module with HART function
SGM3520 8-channel analog output terminal module with HART function
SGM3610 32-channel DI terminal module
SGM3620 32-channel DI relay terminal module (non-I.S)
SGM3710 32-channel DO terminal module
SGM3720 32-channel DO relay terminal module (non-I.S)
SGM3633 Pulse input and overspeed protection terminal module
Cable SGX002 2m, 4m, 5m, 10m and 15m IO Bus communication extension cables used to
connect two racks
SGX006-SGX011 1.5m, 2m, 4m, 6m, 10m and 16m 78-core prefabricated cables used to
connect rack and terminal module
SGX012 3m Modbus module communication expansion cable
Fault detection module SGM8610 External cable fault detection module (used with SGM610 module)
SGM8611 External cable fault detection module (used with SGM610 module)
Occupancy module SGM020 Empty slot occupancy panel in rack
SGM021 Empty slot occupancy module in rack (anti-corrosive European socket)

Product Image
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Packaging & Delivery
Category International Commercial Terms (Incoterms) Terms of Payment Nearest Port
LKS SIL2 SIS CIF, CFR, DAP LC, T/T, D/P Shanghai, Guangzhou, Tianjin

Related Products
LKS SIL2 SIS
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Company Profile
Hollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System SisHollysys High Safety High Availability Hiaguard Sil3 Safety Instruemented System Sis

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours