Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series

Customization: Available
Warranty: 2 Years
Input: 0-2.5V,0-5V,0-10V,0-20mA,4-20mA,0-&etc

Products Details

Basic Info.

Model NO.
ISO 4021 U(A)
Switching Rate
10 Sps
Common Mode Restraint
120 dB
Normal Mode Restraint
60 dB
Input Port Protection
Over-Voltage/Over Current Protection
Response Time
100 Ms Max
Transport Package
35mm DIN Rail-Mounted Type
Specification
ISO9001: 2008, CE, ROHS
Trademark
SUNYUANSZ
Origin
Shenzhen
Production Capacity
50000PCS/Year

Product Description

Modbus RTU Analog Signal Acquisition, RS485/232 Output A-D Converter

ISO4021 Series A-D Converter Features:
-Analog signal acquisition, isolated conversion RS485/232 output
-Testing accuracy>0.05%
-Can be remotely reconfigured for modules accuracy
-Input signal/Output signal: 3000VDC
-Wide power supply range: 8~50V
-High reliability, easy programme, installation.
-Can programme setting module address, baud rate
-Modbus RTU

ISO4021 Series A-D Converter Applications:
-Signal testing/ monitoring /control
-RS232/485 industrial automation control system
-Industial field signal isolation
-Process Monitoring & Control
-Test sensors signal
-Laboratory Data Acquisition
-Medical machine monitoring
-4~20mA/0~20mA signal acquisition

ISO 4021Series A-D Converter Function Description:
ISO 4021 isolated modules to test one channel voltage/current signals, or 2 channel common ground and isolation current/voltage signals.
Anaolg Input Module:
24 bit accuracy, have been calibrated all signal input before ex factor. Also, Users can programme himself, Two input types must be same when testing two signals.
Communication software:
Communication Interface: 1 standard RS485 interface or 2 standard RS232 interface
Communication agreement: Standard ASCII, MODBUS, can make network communicate
With PLC, RTU or watch software.
Data format: 10 bit, 1 start bit, 8 data bits, 1 stop bit.
Communication address (0~255) and baud rate (300600120024004800960019200
38400BPS), Max. Communication distance: 1200m, connect by both twists shiled cable. ± 15KV ESDprotection, communication response time is less than 100mS.
Anti jamming:
Set checksum according to need. Its inside contains MOMENTARY bate diode, can
Restrain surge impulse, protect modules.

ISO 4021 Series A-D Converter Model selection:

ISO 4021A U(A) -

Input voltage or current signal
U1: 0-5V A1: 0-1mA
U2: 0-10V A2: 0-10mA
U3: 0-75mV A3: 0-20mA
U4: 0-2.5V A4: 4-20mA
U5: 0-± 5V A5: 0-± 1mA
U6: 0-± 10V A6: 0-± 10mA
U7: 0-± 100mV A7: 0-± 20mA
U8: Customized A8: Customized

Communication interface
485: Output is RS-485 interface
232: Output is RS-232 interface
232/485: Output is RS-232orRS-485interface, RS232/485 switchover freely
Model no Input Output
ISO 4021 A4-485 4-20mA RS-485
ISO 4021 U1-232 0-5V RS-232
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
Analog to Digital Signal Converter Data Acquisition ISO 4021 U (A) Series
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours