Basic Info.
Model NO.
BA05-AI/I(V)
Certification
CE
Customized
Non-Customized
Product Name
AC Current Transmitter
Brand
OEM ODM
Certificatons
CE
Current Range
AC 0~(8~50)a
Output
DC4~20mA,DC0~20mA,DC1~5V,DC0~5V
Power Consumption
Less Than or Equal to 1W
Accuracy
Class 0.5
Working Power Supply
DC12V 10~15V DC24V 18~30V
Installation Method
Ts35mm DIN Rail Mounting
Transport Package
Fob Shanghai
Trademark
ACREL
Origin
China
Production Capacity
1000PCS/Per Month
Product Description
Product Description BA05-AI/I AC Current Transducer with AC 0-50A input 0-5V output
BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply. They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.
BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit or electrical equipment.The product complies with GB/T13850-1998 and GB1208-2006
.
Features
Technical Parameters
Function
Dimension(Unit:mm)
Installation
Quotation
BA05-AI/I AC Current Transducer with AC 0-50A input 0-5V output
General
BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply. They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit or electrical equipment.The product complies with GB/T13850-1998 and GB1208-2006
.
Features
- Direct AC current measurement up to 600A
- Overload: 1.2 times of rated value
- Applied in Industrial automation
- Overload: 1.2 times of rated value
- Applied in Industrial automation
Technical Parameters
Model Technical parameters | BA05 | BA10 | BA20 | BA50 | |||||
Accuracy | 0.5class,0.2class | ||||||||
Input | Nominal value | AC0~(0.5~10)A | AC 0~( 8~50)A | AC 0~(40~200)A | AC 0~(60~600)A | ||||
Overload | Continual1.2 times, Instantaneous current 10 times/1s: | ||||||||
Absorbed power | ≤1VA | ||||||||
Frequency response | 25Hz~800Hz(average), 25~5kHz(true RMS),specially suitable for power frequency application | ||||||||
Output | Nominal value | DC4~20mA,or 0~20mA,0~5V,0~10V(And so on) | |||||||
Load resistance | Current output ≤500Ω , Voltage output≥1KΩ | ||||||||
Response time | Average≤350ms, true RMS≤100ms | ||||||||
Power supply | Voltage | DC12V or 24V | |||||||
Consumption | ≤1W | ||||||||
Insulation resistance | >100MΩ | ||||||||
Isolation voltage | (Among input//output//power supply)2.0kV/1min,50Hz | ||||||||
Temperature modulus | -10ºC~+55ºC,≤100ppm/ºC | ||||||||
Environment | Temperature | Work:-10ºC~+55ºC Storage:-25ºC~+70ºC | |||||||
Humidity | ≤93%RH,(In the place without dew and corrosive gas) | ||||||||
Altitude | ≤2000m | ||||||||
Installation | (TS35 rail mounting, or attached with screws in of the cabinet) |
Function
Model | Product function | Perforation(mm) | Enter the nominal value range |
BA05-AI/I(V) | 0-10A AC current signal acquisition, output 4-20mA or 0-5V DC signal | Φ5 | AC0~(0.5~10)A |
BA05-AI/I(V)-T | |||
BA10-AI/I(V) | 0-50A AC current signal acquisition, output 4-20mA or 0-5V DC signal | Φ10 | AC0~(8~50)A |
BA10-AI/I(V)-T | |||
BA20-AI/I(V) | AC 0-200A current signal acquisition, output 4-20mA or 0-5V DC signal | Φ20 | AC0~(40~200)A |
BA20-AI/I(V)-T | |||
BA50-AI/I(V) | AC 0-600A current signal acquisition, output 4-20mA or 0-5V DC signal | Φ50 | AC0~(60~600)A |
BA50-AI/I(V)-T |
Dimension(Unit:mm)
Installation
Quotation